CAPACITANCE / TEMPERATURE /FLOW

The combined Capacitance Water Holdup / Temperature / Flowmeter sensors are combined and focused within a short tool section. The short distance between the three sensors enables fluid measurements from the same sample of fluid, delivering accurate in-situ measurements.

APPLICATIONS

  • Accurate measurement of average dielectric constant and temperature response aid in fluid identification inflow diagnoses
  • Accurate quantitative measurement of flowrate in casing and tubing
  • SPECIFICATIONS

    Pressure (max.)     15,000 psi
    Temperature (max.)350 deg F
    Diameter1-3/8"
    Length19.32"
    CWH Resolution1%
    CWH Range—Water holdup0-45%
    Temp. Resolution0.0055 deg F
    Temp. Accuracy+/- 1 deg F
    Temp. Response0.5 sec
    Flowmeter Output10 pulses/revolution
    Threshold CFB Approx.1.7 feet/min
    Threshold CFS Approx5 feet/min

         

    CAPACITANCE ARRAY TOOL (CAT) | GAS HOLDUP TOOL (GHT) | GAMMA RAY | QUARTZ PRESSURE | RADIOACTIVE FLUID DENSITY (RFD) | CAPACITANCE / TEMPERATURE /FLOW