Services




 

 

Mechanical Integrity Services

 

INTERFACING & TOOL COMBINATIONS

  • Simultaneous Operation with other Specialty Cased Hole Logging Tools

 

 

Casing Inspection (Casing Calipers) (MIT 24 Finger)

Radial Bond Logs (RBT)

Temperature Surveys

 

Click Here to download the complete Specialty Cased Hole Technical Catalogue.

Click Here to return to Product Lines.

 

 

Casing Inspection (Casing Calipers) / Multi Finger Imaging Tool (MIT 24 Finger)

 

The 24 finger Multi Finger Imaging Toll (MIT) is used to detect very small changes to the internal surface condition of tubing or casing with a high degree of accuracy.  The MIT can be run through tubing to log casing deeper within a well.

 

 

 

 

APPLICATIONS

 

  • Casing inspection
  • Quantification of scale build-up and corrosion
  • Accurate location of anomalies
  • Identification of items within tubing, buckling and damage
  • Suitable for all well deviations including horizontal
  • 3D visualization capabilities

 

 

SPECIFICATIONS

 

Diameter

1 11/16” (43 mm)

 

Length

64.6” (1,640 mm)

 

Weight

20.7 lbs (9.38 kg)

 

Max. Temperature

350°F (177°C)

 

Max. Pressure

15,000psi (103MPa)

 

 

 

 

 

STANDARD

EXTENDED

Measurement Range

1.75” – 4.5” (45 – 114 mm)

1.75” – 7” (45 – 178 mm)

Radial Resolution

0.002” (0.051 mm)

0.003” (0.076 mm)

Radial Accuracy

± 0.02” (0.508 mm)

± 0.02” (0.508 mm)

Finger Tip Width

0.063” (1.60 mm)

0.063” (1.60 mm)

Finger Contact Force

0.75 – 1.25 lbf (3.4 – 2.7 N)

0.75 – 1.25 lbf (3.4 – 2.7 N)

 

 

 

Vertical Resolution

0.083” (1.27 mm) @ ~ 30 f/min (10 m/min)

Materials

Corrosion Resistant Throughout

Return to top 

 

Radial Bond Logs/Tool (RBT)

 

The RBT measurment is based upon the prinicples of Sonic Attenuation. A traditional Cement Bond Log (CBL) measures the amplitude of  a sonic signal passing along the casing; the signal is reduced where the casing is bonded to the cement. While cement bonds that are either complete, or totally absent, can be clearly identified, signals showing partial bonds provide insufficent data to determine hydraulic isolation. The RBT overcomes this problem by using six (6) receivers positioned circumferentially around the tool. Each receiver provides bond data covering a 1/6th sector of the casing, generating a six segmented “map” of the cement in additon to the conventional CBL and VDL (Variable Density Log).

 

 

                                                    

APPLICATIONS

 

  • Cement bond evaluation
  • Cement channel identification 
  • Bond index calculation (hydraulic isolation effectiveness)
  • Bond attenuation measurement
  • Cement compressive strength
  • Simultaneous cement bond and casing inspection
  • Compressional delta T (computed product), DT

 

 

 

 

 

 

SPECIFICATIONS

 

Diameter

1 11/16” (43 mm)

Length

130.7” (3,320 mm)

Weight

40 lbs (18.1 kg)

Max. Temperature

350 °F (177 °C)

Max. Pressure

20,000 psi (138 MPa)

Receivers

Piezoelectric Crystal (2 ft spacing)

Measurement

6-Channel Radial, 3’ and 5’ Acoustic

Borehole Fluids

Oil, Fresh Water, Brine

Materials

Corrosion Resistant Throughout

Return to top 

 

Temperature Surveys (Capacitance / Temperature / Flowmeter (CTF))

 

Capacitance Water Hold-Up (CWH):  Hydrocarbons and water have different dielectric constants. The output frequency of the probe is in response to the average dielectric constant of the fluids between the cage of the tool and the inner probe. From this the down hole water to hydrocarbon ratio can be derived. 

 

Temperature:  The sensor uses a platinum resistance probe, which changes resistance with temperature. The output signal is multiplied within the electronics to convert to extremely high resolution. The probe tip is very small resulting in a very rapid (0.5 sec) response time.

 

Flowmeter Electronics:  Dual magnets are fitted to the flowmeter main shaft which close Hall effect sensors/switches as the shaft rotates. 5 pickups give a directional output of 10 pulses per revolution.

 

APPLICATIONS

 

  • Fluid compositon from average dielectric constant
  • Fluid ID from temperature response
  • Location of leaks and crossflow by temperature response
  • Quantitative measurement of flowrate in casing and tubing

 

CAPACITANCE WATER HOLD-UP / TEMPERATURE SPECIFICATIONS

 

Diameter

1 3/8” (35 mm)

Length

18.78” (0.47 m)

Weight

4.0 lbs (1.81 kg)

Max. Temperature

350°F (177°C)

Max. Pressure

15,000 psi (103 MPa)

Temp Measure point

8.72” (0.22 m)

CWH Measure point

5.34” (0.13 m)

Power Supply

+12 V @ 25 mA

CWH Resolution

1%

CWH Range

0-45% Water Hold-up

Temp. Resolution

0.0055°F

Temp. Accuracy

+/- 1°F

Temp. Response

<0.5 seconds

Flowmeter Output

10 pulses/Revolution

Material

Corrosion Resistant Throughout

 

 

 

 

 

 

 

 

 

 

 

 

 

                            FLOWMETER SPECIFICATIONS

 

 

Diameter

1 3/8” (35 mm) and 1 11/16” (43 mm)

Length

2.91 ft (890 mm)

Weight *

10 lbs (4.5 kg)*

Max. Temperature

350° F (177° C)

Max. Pressure

15,000 psi (103.4 MPa)

Sensor Measure Point

13.5” (349 mm)

Output

10 pulses/rev (directional)

Sensor Threshold *

~ 1.7 ft/min (0.01 m/s), 100 bpd in 7” CSG

Max Fluid Velocity

500 ft/min (2.54 m/s), 2,850 bpd in 7” CSG

Casing Range

2 3/8” to 9 5/8”

Materials

Corrosion Resistant Throughout

* Dependant on spinner & cage sizes

 

 

Return to top